Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 9.825
Filter
1.
Ann Card Anaesth ; 27(1): 51-52, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722121

ABSTRACT

ABSTRACT: The quadricuspid aortic valve is a rare congenital anomaly, usually associated with aortic regurgitation requiring surgical intervention. It may be associated with other congenital anomalies such as coronary anomalies, patent ductus arteriosus, ventricular septal defect, pulmonary stenosis, and subaortic stenosis. The diagnosis is generally established by either transthoracic or transesophageal echocardiography. Herein, we report a case of a 52-year-old woman who was diagnosed to have quadricuspid aortic valve by intraoperative transesophageal echocardiography.


Subject(s)
Aortic Valve , Echocardiography, Transesophageal , Humans , Female , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Middle Aged , Echocardiography, Transesophageal/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery
2.
Ann Card Anaesth ; 27(1): 53-57, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722122

ABSTRACT

ABSTRACT: Aortic valve (AV) repair is the desired surgical treatment option for young patients with aortic regurgitation (AR). It is considered as a class I indication for the surgical treatment of severeAR. The success of an AV repair depends on the detailed intraoperative transesophageal echocardiographic (TEE) examination which should fulfil the information required by the surgeon. The objective of this echo round is to describe the role of intraoperative TEE in systematic evaluation of the AV, before and after repair.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Echocardiography, Transesophageal , Monitoring, Intraoperative , Humans , Echocardiography, Transesophageal/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Child , Monitoring, Intraoperative/methods
3.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726714

ABSTRACT

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Female , Male , Aged, 80 and over , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Prosthesis Design , Hemodynamics , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Hospital Mortality
4.
Laeknabladid ; 110(5): 247-253, 2024 May.
Article in Icelandic | MEDLINE | ID: mdl-38713559

ABSTRACT

INTRODUCTION: One of the most serious complications of surgical aortic valve replacement (SAVR) is stroke that can result in increased rates of complications, morbidity and mortality postoperatively. The aim of this study was to investigate incidence, risk factors and short-term outcome in a well defined cohort of SAVR-patients. MATERIALS AND METHOD: A retrospective study on 740 consecutive aortic stenosis patients who underwent SAVR in Iceland 2002-2019. Patients with stroke were compared with non-stroke patients; including preoperative risk factors of cardiovascular disease, echocardiogram-results, rate of early postoperative complications other than stroke and 30 day mortality. RESULTS: Mean age was 71 yrs (34% females) with 57% of the patients receiving stented bioprosthesis, 31% a stentless Freestyle®-valve and 12% a mechanical valve. Mean EuroSCORE-II was 3.6, with a maximum preop-gradient of 70 mmHg and an estimated valvular area of 0.73 cm2. Thirteen (1.8%) patients were diagnosed with stroke where hemiplegia (n=9), loss of consciousness (n=3) and/or aphasia (n=4) were the most common presenting symptoms. In 70% of cases the neurological symptoms resolved or disappeared in the first weeks and months after surgery. Only one patient out of 13 died within 30-days (7.7%). Stroke-patients had significantly lower BMI than non-stroke patients, but other risk factors of cardiovascular diseases, intraoperative factors or the rate of other severe postoperative complications than stroke were similar between groups. Total length of stay was 14 days vs. 10 days median, including 2 vs. 1 days in the ICU, in the stroke and non-stroke-groups, respectively. CONCLUSIONS: The rate of stroke after SAVR was low (1.8%) and in line with other similar studies. Although a severe complication, most patients with perioperative stroke survived 30 days postoperatively and in majority of cases neurological symptoms recovered.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Stroke , Humans , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnostic imaging , Male , Aged , Risk Factors , Retrospective Studies , Iceland/epidemiology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Heart Valve Prosthesis Implantation/instrumentation , Stroke/epidemiology , Stroke/mortality , Stroke/etiology , Incidence , Time Factors , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Risk Assessment , Aged, 80 and over , Middle Aged
5.
Sci Rep ; 14(1): 10409, 2024 05 06.
Article in English | MEDLINE | ID: mdl-38710782

ABSTRACT

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Transcatheter Aortic Valve Replacement , Transcatheter Aortic Valve Replacement/methods , Humans , Male , Female , Aged, 80 and over , Aged , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/surgery , Tomography, X-Ray Computed , Aorta/diagnostic imaging , Aorta/surgery , Treatment Outcome , Heart Valve Prosthesis , Retrospective Studies
6.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38691562

ABSTRACT

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Septum , Humans , Male , Female , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Ventricular Septum/diagnostic imaging , Aged, 80 and over , Risk Factors , Aged , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnostic imaging , Heart Conduction System/physiopathology , Heart Conduction System/diagnostic imaging , Treatment Outcome , Predictive Value of Tests , Risk Assessment , Severity of Illness Index , Retrospective Studies , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Multidetector Computed Tomography , Tomography, X-Ray Computed , Action Potentials
7.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article in English | MEDLINE | ID: mdl-38710669

ABSTRACT

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Subject(s)
Aortic Valve , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Hemodynamics , Humans , Hemodynamics/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aged , Female , Male , Aged, 80 and over , Heart Valve Prosthesis Implantation/methods , Echocardiography , Middle Aged , Prosthesis Design
10.
J Cardiothorac Surg ; 19(1): 281, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38715080

ABSTRACT

Injury to coronary arteries during mitral surgery is a rare but life-threatening procedural complication, an anomalous origin and course of the left circumflex artery (LCx) increase this risk. Recognizing the anomaly by the characteristic angiographic pattern and identifying its relationship with the surrounding anatomical structure using imaging techniques, mainly transesophageal echocardiography (TOE) or coronary computed tomography angiography (CCTA), is of crucial importance in setting up the best surgical strategy. We report a case of anomalous origin of a circumflex artery (LCx) from the proximal portion of the right coronary artery (RCA) with a pathway running retroaortically through the mitro-aortic space. An integrated diagnostic approach using a multidisciplinary team with a cardiologist and an imaging radiologist allowed us to decide the surgical strategy. We successfully performed a mitral valvular repair using a minimally invasive minithoracotomic approach and implanting a complete semirigid ring.


Subject(s)
Aortic Valve , Coronary Vessel Anomalies , Echocardiography, Transesophageal , Mitral Valve , Humans , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/abnormalities , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/abnormalities , Coronary Vessel Anomalies/surgery , Coronary Vessel Anomalies/diagnostic imaging , Coronary Angiography , Computed Tomography Angiography , Male , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Female , Coronary Vessels/surgery , Coronary Vessels/diagnostic imaging
12.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38573257

ABSTRACT

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Postoperative Complications , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Postoperative Complications/surgery , Prosthesis Design , Randomized Controlled Trials as Topic , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Incidence , Retreatment
13.
Surg Innov ; 31(3): 256-262, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38565982

ABSTRACT

OBJECTIVE: In this case report, the auxiliary role of deep learning and 3-dimensional printing technology in the perioperative period was discussed to guide transcatheter aortic valve replacement and coronary stent implantation simultaneously. CASE PRESENTATION: A 68-year-old man had shortness of breath and chest tightness, accompanied by paroxysmal nocturnal dyspnea, 2 weeks before presenting at our hospital. Echocardiography results obtained in the outpatient department showed severe aortic stenosis combined with regurgitation and pleural effusion. The patient was first treated with closed thoracic drainage. After 800 mL of pleural effusion was collected, the patient's symptoms were relieved and he was admitted to the hospital. Preoperative transthoracic echocardiography showed severe bicuspid aortic valve stenosis combined with calcification and aortic regurgitation (mean pressure gradient, 42 mmHg). Preoperative computed tomography results showed a type I bicuspid aortic valve with severe eccentric calcification. The leaflet could be seen from the left coronary artery plane, which indicated an extremely high possibility of coronary obstruction. After preoperative imaging assessment, deep learning and 3-dimensional printing technology were used for evaluation and simulation. Guided transcatheter aortic valve replacement and a coronary stent implant were completed successfully. Postoperative digital subtraction angiography showed that the bioprosthesis and the chimney coronary stent were in ideal positions. Transesophageal echocardiography showed normal morphology without paravalvular regurgitation. CONCLUSION: The perioperative guidance of deep learning and 3-dimensional printing are of great help for surgical strategy formulation in patients with severe bicuspid aortic valve stenosis with calcification and high-risk coronary obstruction.


Subject(s)
Aortic Valve Stenosis , Deep Learning , Printing, Three-Dimensional , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Male , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Stents , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/abnormalities , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging
14.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Article in English | MEDLINE | ID: mdl-38577923

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Subject(s)
Aortic Dissection , Aortic Valve Insufficiency , Aortic Valve , Blood Vessel Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aortic Dissection/surgery , Aortic Dissection/diagnostic imaging , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Middle Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Prosthesis Design , Blood Vessel Prosthesis , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortography
15.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Article in English | MEDLINE | ID: mdl-38577939

ABSTRACT

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Subject(s)
Aortic Valve Stenosis , Balloon Valvuloplasty , Bicuspid Aortic Valve Disease , Heart Valve Prosthesis , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Male , Female , Retrospective Studies , Treatment Outcome , Bicuspid Aortic Valve Disease/physiopathology , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/mortality , Bicuspid Aortic Valve Disease/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Time Factors , Aged , Balloon Valvuloplasty/adverse effects , Balloon Valvuloplasty/mortality , Aged, 80 and over , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/abnormalities , Recovery of Function , Hemodynamics , Risk Assessment
16.
Catheter Cardiovasc Interv ; 103(6): 1069-1073, 2024 May.
Article in English | MEDLINE | ID: mdl-38584521
17.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Article in English | MEDLINE | ID: mdl-38577931

ABSTRACT

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Postoperative Complications , Prospective Studies , Recovery of Function , Risk Factors , Spain , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
19.
JACC Cardiovasc Interv ; 17(8): 1020-1028, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38658116

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective and safe therapy for severe aortic stenosis. Rapid or fast pacing is required for implantation, which can be performed via a pre-existing cardiac implantable electric device (CIED). However, safety data on CIEDs for pacing in TAVR are missing. OBJECTIVES: The aim of this study was to elucidate procedural safety and feasibility of internal pacing with a CIED in TAVR. METHODS: Patients undergoing TAVR with a CIED were included in this analysis. Baseline characteristics, procedural details, and complications according to Valve Academic Research Consortium 3 (VARC-3) criteria after TAVR were compared between both groups. RESULTS: A total of 486 patients were included. Pacing was performed using a CIED in 150 patients and a transient pacemaker in 336 patients. No differences in technical success according to VARC-3 criteria or procedure duration occurred between the groups. The usage of transient pacers for pacing was associated with a significantly higher bleeding rate (bleeding type ≥2 according to VARC-3-criteria; 2.0% vs 13.1%; P < 0.01). Furthermore, impairment of the CIED appeared in 2.3% of patients after TAVR only in the group in which pacing was performed by a transient pacer, leading to surgical revision of the CIED in 1.3% of all patients when transient pacemakers were used. CONCLUSIONS: Internal pacing using a CIED is safe and feasible without differences of procedural time and technical success and might reduce bleeding rates. Furthermore, pacing using a CIED circumvents the risk of lead dislocation. Our data provide an urgent call for the use of a CIED for pacing during a TAVR procedure in general.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Cardiac Pacing, Artificial , Feasibility Studies , Hospitals, High-Volume , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Female , Male , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Treatment Outcome , Time Factors , Aged , Risk Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Retrospective Studies , Severity of Illness Index , Risk Assessment
SELECTION OF CITATIONS
SEARCH DETAIL
...